{"product_id":"schneider-residual-current-circuit-breakerrccb","title":"Schneider Acti9 Residual Current Circuit Breaker, RCCB","description":"\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schneider Electric (Global Leader in Electrical Safety)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e Acti9 - Professional RCCB Range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Function:\u003c\/strong\u003e RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife-Saving Sensitivity:\u003c\/strong\u003e 30mA detection prevents electric shock in ≤40ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulatory Compliance:\u003c\/strong\u003e NBC (National Building Code) mandatory for wet areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Features:\u003c\/strong\u003e Earth fault indication, test button, DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Applications:\u003c\/strong\u003e Bathroom, kitchen, swimming pool, outdoor installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Scope:\u003c\/strong\u003e Electric shock, fire hazard, equipment damage prevention\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv style=\"background-color: ?fcefb9; padding: 15px; border-left: 4px solid ?efc41a; margin: 15px 0; border-radius: 5px;\"\u003e\n\u003ch4 style=\"color: ?000000; margin-top: 0;\"\u003e⚡ Life-Saving Technology: RCCB is NOT Optional\u003c\/h4\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Shock Prevention:\u003c\/strong\u003e 30mA sensitivity detects dangerous leakage before it can harm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLightning-Fast Response:\u003c\/strong\u003e Trips in ≤40ms - faster than human nerve response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulatory Mandatory:\u003c\/strong\u003e NBC requires RCCB for bathrooms, wet areas, outdoor circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsurance Compliance:\u003c\/strong\u003e Reduces liability and may lower insurance premiums\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFamily Protection:\u003c\/strong\u003e Essential safety for children, elderly, vulnerable family members\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSchneider Electric Acti9 RCCB (Residual Current Circuit Breaker)\u003c\/strong\u003e is a life-saving safety device that detects earth leakage currents as low as 30mA and disconnects the circuit in milliseconds to prevent electric shock, fire hazards, and equipment damage. This is not just another electrical component—it's a critical safety system that can mean the difference between life and death in electrical fault situations.\u003c\/p\u003e\n\u003cp\u003eUnlike traditional MCBs that only protect against overcurrent, RCCB monitors current imbalance between live and neutral wires, instantly detecting when current 'leaks' through unintended paths—including through human body contact with live parts. With Schneider's advanced French engineering, the Acti9 RCCB provides reliable protection mandated by safety codes and preferred by electrical professionals worldwide.\u003c\/p\u003e\n\u003ch3\u003eWhy RCCB is Essential: Understanding Earth Leakage\u003c\/h3\u003e\n\u003cdiv style=\"background-color: ?e3f2fd; padding: 15px; border-left: 4px solid ?1aa4ef; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003ch4 style=\"color: ?000000; margin-top: 0;\"\u003e🔍 How Earth Leakage Occurs \u0026amp; Why It's Deadly\u003c\/h4\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Failure:\u003c\/strong\u003e Aging wires, moisture, heat damage conductor insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Faults:\u003c\/strong\u003e Appliance internal faults create conductive paths to metal parts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHuman Contact:\u003c\/strong\u003e Touching live parts creates current path through body to ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Ingress:\u003c\/strong\u003e Moisture in electrical connections creates leakage paths\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Errors:\u003c\/strong\u003e Poor connections, damaged cables during construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Factors:\u003c\/strong\u003e Rodents, corrosion, vibration damage over time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCritical Applications: Where RCCB Saves Lives\u003c\/h3\u003e\n\u003cdiv style=\"background-color: ?d4edda; padding: 15px; border-left: 4px solid ?328616; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003ch4 style=\"color: ?000000; margin-top: 0;\"\u003e🏠 Mandatory \u0026amp; Recommended RCCB Installations\u003c\/h4\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMANDATORY - Bathroom Circuits:\u003c\/strong\u003e Wet environment + electrical = lethal combination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMANDATORY - Swimming Pool:\u003c\/strong\u003e Water + electricity requires immediate disconnection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMANDATORY - Outdoor Installations:\u003c\/strong\u003e Weather exposure increases fault probability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRECOMMENDED - Kitchen Circuits:\u003c\/strong\u003e Water exposure near electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRECOMMENDED - Children's Areas:\u003c\/strong\u003e Enhanced protection for curious kids\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRECOMMENDED - Elderly Care:\u003c\/strong\u003e Slower reflexes need faster electrical protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOMMERCIAL - Workshop Areas:\u003c\/strong\u003e Power tools + human contact = high risk\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINDUSTRIAL - Medical Facilities:\u003c\/strong\u003e Patient safety during electrical procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProfessional Installation Features\u003c\/h3\u003e\n\u003cdiv style=\"background-color: ?fcefb9; padding: 15px; border-left: 4px solid ?efc41a; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003ch4 style=\"color: ?000000; margin-top: 0;\"\u003e🔧 Schneider Acti9 Professional Features\u003c\/h4\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Fault Indication:\u003c\/strong\u003e Red mechanical indicator shows fault occurrence\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnified Terminal Design:\u003c\/strong\u003e Clear wiring indication prevents installation errors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Standard 35mm rail for easy panel integration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaptive Padlocking:\u003c\/strong\u003e Security feature prevents unauthorized operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -5°C to +40°C suitable for Indian climate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP20 Protection:\u003c\/strong\u003e Panel-mount protection against finger contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCommercial \u0026amp; Industrial Benefits\u003c\/h3\u003e\n\u003cdiv style=\"background-color: ?d4edda; padding: 15px; border-left: 4px solid ?328616; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003ch4 style=\"color: ?000000; margin-top: 0;\"\u003e🏢 Business Case for RCCB Installation\u003c\/h4\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmployee Safety:\u003c\/strong\u003e Prevent workplace electrical accidents and compensation claims\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Protection:\u003c\/strong\u003e Prevent costly equipment damage from earth faults\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDowntime Reduction:\u003c\/strong\u003e Early fault detection prevents system failures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire Prevention:\u003c\/strong\u003e Reduce property damage risk from electrical faults\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProductivity:\u003c\/strong\u003e Fewer electrical interruptions, safer work environment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReputation:\u003c\/strong\u003e Safety-conscious company image attracts better talent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eReal-World Safety Statistics\u003c\/h3\u003e\n\u003cdiv style=\"background-color: ?fcefb9; padding: 15px; border-left: 4px solid ?efc41a; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003ch4 style=\"color: ?000000; margin-top: 0;\"\u003e📊 Why Every Second Matters in Electrical Safety\u003c\/h4\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFatal Current:\u003c\/strong\u003e 30mA through heart for 30 seconds can be fatal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNerve Response:\u003c\/strong\u003e Human reflexes take 150-300ms to react\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCCB Response:\u003c\/strong\u003e 40ms trip time - 4x faster than human nerves\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccident Statistics:\u003c\/strong\u003e 70% electrical accidents occur in wet conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChild Safety:\u003c\/strong\u003e Lower body resistance makes children more vulnerable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElderly Risk:\u003c\/strong\u003e Slower reflexes and medical conditions increase danger\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCost of Life:\u003c\/strong\u003e No amount of money equals the value of human life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eBangalore Safety Delivery Network\u003c\/h3\u003e\n\u003cdiv style=\"background-color: ?e3f2fd; padding: 15px; border-left: 4px solid ?1aa4ef; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLife-Saving RCCB Delivery:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e60-Minute:\u003c\/strong\u003e Koramangala, HSR Layout, Indiranagar, Jayanagar, Malleshwaram \u0026amp; More\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90-Minute:\u003c\/strong\u003e Electronic City, Whitefield, Marathahalli, JP Nagar, Hebbal \u0026amp; More\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120-Minute:\u003c\/strong\u003e Banashankari, Rajajinagar, Yelahanka, BTM Layout, Basavanagudi \u0026amp; More\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Upgrades:\u003c\/strong\u003e Prioritized delivery for bathroom and wet area installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eReturns \u0026amp; Exchange Policy\u003c\/h2\u003e\n\u003col type=\"1\"\u003e\n\u003cli\u003eReturn Within 24 Hours of delivery under the following conditions:\n\u003col class=\"sub-item\"\u003e\n\u003cli\u003eDamaged or defective product.\u003c\/li\u003e\n\u003cli\u003eWrong or missing product.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct cannot be returned once used.\u003c\/li\u003e\n\u003cli\u003eRefer to Refund Policy for details.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003c!----\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"2 Pole \/ 25A \/ 30mA","offer_id":63136916111729,"sku":"SCH-RCCB-2P-25A-30MA","price":1600.0,"currency_code":"INR","in_stock":true},{"title":"2 Pole \/ 40A \/ 30mA","offer_id":63136916144497,"sku":"SCH-RCCB-2P-40A-30MA","price":1870.0,"currency_code":"INR","in_stock":true},{"title":"2 Pole \/ 63A \/ 30mA","offer_id":63136916177265,"sku":"SCH-RCCB-2P-63A-30MA","price":2250.0,"currency_code":"INR","in_stock":true},{"title":"4 Pole \/ 25A \/ 30mA","offer_id":63136916210033,"sku":"SCH-RCCB-4P-25A-30MA","price":2440.0,"currency_code":"INR","in_stock":true},{"title":"4 Pole \/ 40A \/ 30mA","offer_id":63136916242801,"sku":"SCH-RCCB-4P-40A-30MA","price":2440.0,"currency_code":"INR","in_stock":true},{"title":"4 Pole \/ 63A \/ 30mA","offer_id":63136916275569,"sku":"SCH-RCCB-4P-63A-30MA","price":2780.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0976\/3985\/8545\/files\/612LTO2AFzL._SL1500_cc95f34d-d71a-42c1-a89b-7fb2bebf1331.jpg?v=1769776534","url":"https:\/\/materialrunner.in\/products\/schneider-residual-current-circuit-breakerrccb","provider":"MaterialRunner","version":"1.0","type":"link"}