{"product_id":"vip-electrical-conduit-pipe-frls-3m-length","title":"VIP Electrical Conduit Pipe, FRLS, 3m Length","description":"\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ch3\u003eQuick Answer: What is VIP Electrical Conduit Pipe used for?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVIP Electrical Conduit Pipe, FRLS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erigid UPVC electrical conduit system\u003c\/strong\u003e, designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econcealed and surface wiring installations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith fire retardant and low smoke properties for enhanced safety.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRigid UPVC (Unplasticized Polyvinyl Chloride)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConforms to IS: 9537 (Part - 3) 1983\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 metres per pipe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Sizes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19mm and 25mm diameter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrades:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMMS (Medium Mechanical Stress) and HMS (Heavy Mechanical Stress)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Feature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFRLS - Fire Retardant, Low Smoke\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack and White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eVIP Electrical Conduit Pipe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a premium quality rigid UPVC conduit system manufactured by VIP Extrusions, designed to protect electrical wiring in residential, commercial, and industrial installations. The FRLS (Fire Retardant, Low Smoke) formulation ensures enhanced safety by preventing fire spread and minimizing toxic smoke emission in case of fire.\u003c\/p\u003e\n\u003cp\u003eAvailable in two mechanical stress grades—MMS for standard applications and HMS for heavy-duty installations—this conduit pipe offers superior impact resistance, corrosion protection, and long-term durability. The 3-metre length allows for efficient installation with minimal joints, reducing potential failure points in your electrical system.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch4\u003eTechnical Specifications (Quick Reference)\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRigid UPVC (Unplasticized Polyvinyl Chloride)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS: 9537 (Part - 3) 1983 | BIS License # CM\/L 0941959\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable Diameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19mm, 25mm (other sizes: 16mm, 20mm, 32mm, 40mm, 50mm available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Grades\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMMS (Medium Mechanical Stress), HMS (Heavy Mechanical Stress)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFRLS - Fire Retardant, Low Smoke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack, White\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRecommended Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConcealed conduit installation in walls and ceilings for homes and apartments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Buildings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOffice spaces, retail stores, and showrooms requiring safe electrical distribution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Facilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactories and warehouses where heavy-duty HMS grade provides extra protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRenovation Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSurface mounting applications where existing structures need electrical upgrades\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire-Sensitive Areas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLocations requiring enhanced fire safety compliance with FRLS properties\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Installations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWeather-resistant UPVC suitable for external conduit runs (with proper UV protection)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan the Route:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMark conduit path ensuring minimum bends and proper support spacing (max 1 metre intervals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCut to Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse a hacksaw or pipe cutter for clean, square cuts; deburr edges with a file\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJoin Pipes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse VIP PVC solvent cement with appropriate couplers, bends, and junction boxes for connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFix conduit using saddles or clamps at regular intervals; ensure proper alignment before cementing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Pulling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllow solvent joints to cure for 24 hours before pulling cables; use fish tape or draw wire for easier cable installation\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003ch3\u003e1) What is the difference between MMS and HMS grade conduit pipes?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMMS (Medium Mechanical Stress)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egrade is suitable for standard residential and light commercial applications, while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMS (Heavy Mechanical Stress)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egrade offers thicker walls and higher impact resistance for industrial environments, areas with heavy foot traffic, or installations requiring extra durability.\u003c\/p\u003e\n\u003ch3\u003e2) What does FRLS mean and why is it important?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFRLS stands for Fire Retardant, Low Smoke\u003c\/strong\u003e. This property ensures the conduit pipe resists ignition and flame spread, while producing minimal toxic smoke in case of fire. This is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical for safety compliance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein commercial buildings and multi-story residential complexes where fire safety regulations are stringent.\u003c\/p\u003e\n\u003ch3\u003e3) Can I use this conduit pipe for outdoor installations?\u003c\/h3\u003e\n\u003cp\u003eYes,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUPVC conduit pipes are weather-resistant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand suitable for outdoor use. However, for prolonged direct sunlight exposure, consider using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUV-stabilized variants or painting with UV-resistant paint\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent degradation. The material is naturally resistant to moisture, corrosion, and most chemicals.\u003c\/p\u003e\n\u003ch3\u003e4) How do I join VIP conduit pipes together?\u003c\/h3\u003e\n\u003cp\u003eVIP conduit pipes are joined using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esolvent cement welding\u003c\/strong\u003e. Apply VIP PVC solvent to both the pipe end and the coupler\/fitting socket, insert firmly, and hold for 15-30 seconds. Allow\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 hours curing time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebefore pulling cables. Use appropriate bends, couplers, and junction boxes from the VIP range for best compatibility.\u003c\/p\u003e\n\u003ch3\u003e5) What cable capacity can I expect in 19mm and 25mm conduit?\u003c\/h3\u003e\n\u003cp\u003eAs a general guideline,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e19mm conduit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan accommodate 3-4 cables of 1.5 sq.mm or 2-3 cables of 2.5 sq.mm.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25mm conduit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan handle 5-6 cables of 1.5 sq.mm or 4-5 cables of 2.5 sq.mm. Always follow\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEC\/IEC fill ratio guidelines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(maximum 40% fill) and local electrical codes for safe installation.\u003c\/p\u003e\n\u003ch3\u003e6) Is this conduit pipe compatible with other brands' fittings?\u003c\/h3\u003e\n\u003cp\u003eWhile VIP conduit pipes follow\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS: 9537 standards\u003c\/strong\u003e, we recommend using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVIP brand fittings, bends, and accessories\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor guaranteed compatibility and optimal joint strength. Mixing brands may result in improper fit or weak solvent joints that could fail over time.\u003c\/p\u003e\n\u003ch3\u003e7) How many support saddles do I need per pipe length?\u003c\/h3\u003e\n\u003cp\u003eFor proper support, install saddles or clamps at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaximum 1-metre intervals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor horizontal runs and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.5-metre intervals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor vertical runs. For 3-metre pipes, use at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3-4 support points\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent sagging and maintain alignment, especially before the solvent joints have fully cured.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy from MaterialRunner?\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuthentic VIP Hardware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerified genuine products with BIS certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Conduit System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull range of pipes, bends, couplers, and junction boxes available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBangalore Fulfilment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuick local availability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"VIP","offers":[{"title":"19mm \/ MMS \/ Black","offer_id":63174883639665,"sku":null,"price":70.0,"currency_code":"INR","in_stock":true},{"title":"19mm \/ MMS \/ White","offer_id":63174883672433,"sku":null,"price":70.0,"currency_code":"INR","in_stock":true},{"title":"19mm \/ HMS \/ Black","offer_id":63174883705201,"sku":null,"price":87.0,"currency_code":"INR","in_stock":true},{"title":"19mm \/ HMS \/ White","offer_id":63174883737969,"sku":null,"price":87.0,"currency_code":"INR","in_stock":true},{"title":"25mm \/ MMS \/ Black","offer_id":63174883770737,"sku":null,"price":100.0,"currency_code":"INR","in_stock":true},{"title":"25mm \/ MMS \/ White","offer_id":63174883803505,"sku":null,"price":100.0,"currency_code":"INR","in_stock":true},{"title":"25mm \/ HMS \/ Black","offer_id":63174883836273,"sku":null,"price":115.0,"currency_code":"INR","in_stock":true},{"title":"25mm \/ HMS \/ White","offer_id":63174883869041,"sku":null,"price":115.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0976\/3985\/8545\/files\/electrical-pvc-conduit-pipe-vip-brand-20mm-mms-isi.jpg?v=1769776780","url":"https:\/\/materialrunner.in\/products\/vip-electrical-conduit-pipe-frls-3m-length","provider":"MaterialRunner","version":"1.0","type":"link"}